Markets

Four markets. One platform.

ISO and RTO studies for system operators, compliance and modeling for generation owners, grid-code compliance for data centers and large loads, and the substation record for transmission owners, all on the same models, requirements and procedures.

01 · ISO and RTO studies

System operators: every model submission, tested the same way.

System operators contract GridStrong to run automated model quality testing across the interconnection queue: PSCAD and PSS®E packages retrieved, tested in isolated environments against the operator's own rulebook, and returned with pass or fail and the evidence, through an API-to-API integration or the Dashboard.

  • EMT and dynamic model quality tests at queue scale
  • Operator-specific test suites, kept current with the operator's test manual
  • Results delivered to the operator's systems, not a consultant's inbox

See the model quality testing case study

02 · Generation

Generation owners: from interconnection request to operational compliance.

Owners of wind, solar, storage, hybrid and synchronous plants run the whole lifecycle in one record: interconnection modeling and model quality testing before commercial operation, then NERC and ISO compliance, event analysis and asset management after it.

  • Pre-COD: application models, cluster studies, GIA obligations, commissioning
  • Post-COD: PRC-019, PRC-024, PRC-028, PRC-029, PRC-030, MOD-025, MOD-026, MOD-027, MOD-032 and regional programs
  • Disturbance monitoring and event analysis on the operating fleet

See the fleet gap analysis case study

03 · Data centers and large loads

Data centers and large loads: the next terawatt connects through the same grid code.

Data centers and other computational loads now carry NERC and ISO/RTO requirements of their own: registration, interconnection studies, models, ride-through and operating data. GridStrong is the compliance expert that takes the site through all of it and keeps the record for the operator and the developer.

  • Computational-load plant profiles and the load-side model
  • Interconnection studies and ride-through evaluations
  • Requirements tracking as the standards for large load take shape

More on data centers

04 · Transmission

Transmission owners: every substation, rating and scheme on one record.

If you own substations at 69 kV and above, GridStrong is your system of record. It is the same approach that runs a generation fleet, applied to the work of a Transmission Owner: what is in each substation, how it is rated and protected, which schemes and agreements govern it, and the evidence behind every NERC requirement.

  • Substation inventory from the one-line out: transformers, breakers, relays and their settings
  • Facility Ratings Methodology and the ratings for every element under FAC-008-5
  • Protection system maintenance under PRC-005-6 and relay loadability under PRC-023-6
  • Remedial Action Schemes under PRC-012-2, with maintenance and testing under PRC-017-1
  • Disturbance monitoring under PRC-002-5 and BES Cyber System categorization under CIP-002
  • Interconnection and operating agreements kept with the substation, their obligations tracked as tasks

See the compliance modules